How to prepare an AS9102 Form 3 Excel working copy
AS9102 Form 3 connects each design characteristic with its requirement and actual inspection result. Use this guide to link drawing balloons to checked rows, prepare an editable Excel working copy and review it before submission.
Start with a ballooned drawing, not an assumed result
A ballooned drawing assigns an identifier to a requirement so the reviewer can find the corresponding inspection row. Numbering a callout does not verify its wording, tolerance or measured result. BalloonFAI assists with recognition and report preparation; every entry needs human review.
You will need the governing drawing and revision, the identified part or serial/lot, applicable customer requirements and genuine inspection evidence. This guide uses an invented dimensional example, not a customer FAIR or proof of product acceptance.
For the official template, start at IAQG's 9102 forms page, which lists revision C and B downloads. Confirm the revision and customer instructions that govern your report. BalloonFAI exports its own editable working copies; they are not an IAQG-issued certification or approval.
1. Start with the correct drawing
Open your PDF or ASCII DXF in BalloonFAI. For a multi-page PDF, choose the working page. Find callouts automatically, then box anything missed. Compare every entry with the drawing: text, symbols, quantity, units and location. Check notes and special requirements as well as dimensions. Recognition helps prepare the list; you still check its coverage.
2. Establish report identity
Open Report details — Forms 1, 2 and 3. Enter the part number and name, inspected serial number and FAIR identifier. Check the part revision, drawing number and drawing revision in Form 1. These records identify the part and report; a filename alone is insufficient. Each PDF page has its own report, so check the selected page before exporting.
3. Check each requirement and its limits
Match each balloon number to the corresponding characteristic row. Keep the requirement faithful to the drawing, including its tolerance and any qualifications. Verify the reference location and units. Confirm a tentative type before relying on calculated limits, and separately check edited limits against the drawing.
Apply general tolerances only when the drawing specifies them. The ISO 2768-1:1989 calculator and ISO 286 fit calculator can help check supported values. They do not establish which requirement applies to your part. Leave ambiguous requirements for review rather than substituting a convenient tolerance.
4. Record what was actually measured
A requirement and a result are different records. In this synthetic example, 25 ±0.1 mm gives limits of 24.9 to 25.1 mm. A reading of 25.02 mm is a result only after measuring the identified part. Do not copy the nominal value into Results.
Enter genuine inspection results in the exported workbook. Pro also has an Import CMM results workflow, but a real equipment export still needs to be validated for your format, units and device-to-balloon mapping. This guide's worked example does not demonstrate a verified equipment integration. Check the part and serial identity; reimport if the report identity or revisions change, and retain original readings and source evidence for review.
A requirement-to-result example
This illustrative row shows the difference between the drawing requirement, calculated limits and a measured result. Use your own drawing reference and actual measurement records for a real part.
| Balloon | Reference | Requirement | Checked limits | Illustrative reading |
|---|---|---|---|---|
| 1 | Sheet 1, A2 | 25 ±0.1 mm | 24.9–25.1 mm | 25.02 mm |
For this row, a value inside the limits addresses only the shown dimensional check. It does not establish drawing coverage, the validity of an inspection method or approval of the part. Keep missing or uncertain entries marked for review.
5. Resolve review items and investigate exceptions
Use export review to return to the relevant balloon or report field. Readings and limits have separate checks. Resolve missing limits, uncertain recognition and stale measurements against their sources. An out-of-limit CMM result needs investigation even when the displayed, rounded value appears to equal a limit. Follow the original reading in CMM Measurements. Highlighting does not assign a disposition or create a nonconformance number.
6. Export a working copy for review
Choose Export Form 3 or Export Forms 1–3, and download the ballooned PDF. Check numbers, requirements, results and unresolved comments in the files. Complete applicable tooling and nonconformance references, and arrange authorized review and approval under your procedures. Form 3 alone is not a complete FAIR; the report also includes Forms 1 and 2 and applicable supporting evidence. Exporting does not approve the part.
IAQG lists the 9102C forms, including the official Form 3 download. Consult the applicable standard and customer requirements for completion rules. The form downloads do not replace access to the governing standard or your customer's instructions. BalloonFAI exports its own worksheets, not an IAQG-issued approval.
Try the drawing-to-working-copy workflow
Open a PDF or ASCII DXF, review the numbered characteristics and export a ballooned PDF plus Form 3 or Forms 1–3 Excel working copies. The free signed-in plan allows three different drawings per month; this guide and the tolerance calculators can be read without signing in.
Drawing file contents are processed on your device. Online services handle account, file-fingerprint, usage and billing information; read the privacy notice. Check your organization's document-handling rules before opening a drawing.