Ballooned drawing PDF: connect callouts to your FAI report

A ballooned drawing has numbered markers beside its requirements. Those numbers connect the drawing to corresponding inspection-report rows, so a reviewer can trace a result back to its source. Ballooning prepares that link; it does not prove that a part meets the requirement.

What does balloon drawing software help you prepare?

For a machining shop, quality engineer or supplier preparing a first article inspection (FAI), the immediate task is to build a traceable list of drawing requirements. BalloonFAI helps you number PDF callouts, review captured text and limits, and export a ballooned PDF with editable Excel inspection working copies.

The drawing and the report serve different purposes: the PDF shows where a characteristic comes from; the report holds its requirement and inspection record. Keep their numbering and revisions consistent. For AS9102 work, check your governing revision and customer instructions, then use the Form 3 preparation guide.

Five steps from a PDF drawing to an Excel working copy

  1. Open the correct drawing. In BalloonFAI, open the PDF and confirm its part number, drawing revision, units and selected page. Keep customer instructions available. A filename alone does not establish report identity.
  2. Number the requirements. Use PDF-text capture or OCR assistance, then inspect the drawing and box anything missed. Check dimensions, notes, quantities, symbols and relevant special requirements. Review missing or duplicate balloons; recognition is an aid, not a coverage or accuracy guarantee.
  3. Review the text and limits. Match each numbered entry to the printed callout and its location. Confirm the characteristic type, units and tolerances. Apply a general tolerance only when the drawing specifies it, and keep uncertain requirements marked for review.
  4. Measure the identified part. Keep the requirement separate from the result. Enter genuine inspection readings in the exported workbook and retain their supporting evidence. A nominal dimension or calculated limit is not a measured result.
  5. Export and check both files. Download the ballooned PDF and Form 3 or Forms 1–3 Excel working copies. Open them, compare balloon numbers with report rows, and resolve review comments. Re-export and recheck both files after relevant edits, then follow your review and approval procedures.

Example: balloon 2 links a thickness callout to limits

In BalloonFAI's own English MP-2041 sample drawing below, balloon 2 identifies 12 ±0.1 mm. Its lower limit is 12 − 0.1 = 11.9 mm; its upper limit is 12 + 0.1 = 12.1 mm. The same number lets a reviewer find the corresponding requirement row in the exported report.

BalloonFAI demonstration requirement — no physical inspection result is shown
BalloonRequirementLower limitUpper limit
212 ±0.1 mm11.9 mm12.1 mm
Local BalloonFAI demonstration of the English MP-2041 mounting plate: nine numbered callouts and characteristic rows, including balloon 2 with 11.9 and 12.1 mm limits.
BalloonFAI's built-in MP-2041 English sample, captured locally on . This earlier interface is a local product demonstration, not a current production screenshot or a customer case.

The example shows a requirement and calculated limits only. It does not demonstrate that a physical part was measured, that every requirement was captured, or that a FAIR was approved.

Check the tolerance source before completing the report

An individually specified tolerance belongs with its own callout. For supported untoleranced dimensions on a drawing that invokes the older edition, use the ISO 2768-1:1989 calculator; it does not implement ISO 2768:2026. For supported hole and shaft fit designations, use the ISO 286 fits calculator. Neither tool decides which requirement applies to your part.

A ballooned drawing and an Excel file are working documents. They do not replace the applicable standard, customer-specific requirements, inspection evidence or authorized approval. For official revision-controlled forms, see IAQG's 9102 forms page. Northrop Grumman's 2023 supplier FAI guide is one public example of drawing-to-characteristic traceability; follow the instructions that govern your own job.

Try the PDF workflow with a drawing you are permitted to use

The free signed-in plan allows three different drawings per month. Reopening the same unchanged drawing in that month does not use another free drawing. You can start by examining the built-in English sample, then use your own permitted PDF and review every captured characteristic.

Drawing file contents are processed on your device. Online services handle account, file-fingerprint, usage and billing information; see the privacy notice. Check your organization's document-handling rules before opening a drawing.

This demonstration does not establish a validated Pro team, CMM equipment import or customer PPAP submission workflow. Those capabilities still need validation with the actual team roles, measuring-device exports or customer submission examples for the intended use.

Try BalloonFAI free — 3 drawings a month

Maintained by BalloonFAI. Updated . Questions or corrections: [email protected].